Ecochill R-515B is a blended hydrofluoroolefin (HFO) and hydrofluorocarbon (HFC) refrigerant developed for low-pressure chiller and compatible cooling applications. It is designed as a lower-global-warming-potential alternative to R-123 in suitable equipment. R-515B offers stable performance for compatible chillers and commercial or industrial cooling systems designed for this refrigerant. It has zero ozone depletion potential (ODP) and a very low global warming potential (GWP), helping reduce the environmental impact associated with refrigerant use. R-515B is classified as an A1 refrigerant, meaning it has lower toxicity and no flame propagation under the standard classification test. Ecochill R-515B should only be used in equipment designed for or approved to operate with this refrigerant, following manufacturer recommendations and applicable regulations.

Packaging

  • Refillable Cylinders
  • Disposable Cylinders
  • Tonners
  • ISO Tanks
  • Bulk Supply

Custom packs: on enquiry Fill weights, container compatibility and availability must be confirmed product by product

APPLICATIONS

  • Low-Pressure Chillers: Suitable for compatible chiller systems designed for R-515B.
  • Commercial Cooling: Used in approved commercial cooling equipment.
  • Industrial Cooling: Suitable for compatible industrial cooling and refrigeration systems.
  • Building HVAC Systems: Supports approved central cooling applications in commercial buildings.
  • Chiller Replacement Applications: Can be considered as an alternative to R-123 in selected systems when approved by the equipment manufacturer.

USAGE INSTRUCTIONS

  • Use Ecochill R-515B only in equipment specifically designed or approved for this refrigerant.
  • Do not use R-515B as a direct drop-in replacement for R-123 unless the equipment manufacturer explicitly approves the conversion.
  • Follow the equipment manufacturer’s instructions for refrigerant charging, servicing, leak testing, and system maintenance.
  • Use suitable recovery equipment and approved procedures when handling or transferring refrigerant.
  • Never intentionally release refrigerant into the atmosphere. Recover it in accordance with applicable regulations.
  • Store cylinders in a cool, dry, well-ventilated area away from excessive heat and direct sunlight.
  • Consult the product Safety Data Sheet (SDS) and follow all applicable environmental and workplace safety requirements.